Main performance parameters of GM series mechanical diaphragm metering pump

● maximum flow of single head: 500L / h

● maximum discharge pressure: 12bar

● regulation ratio 10:1, steady-state accuracy 2%

● suction lifting height up to 3m water column

● the maximum inlet pressure is 2 bar

● the maximum allowable material temperature is 40C

Main features of GM series mechanical diaphragm metering pump

Drive end

● variable eccentric mechanism adjustment to ensure smooth flow pulsation

● enhanced structural design, suitable for harsh operating environment

● wear resistant ball bearing makes the work more stable

● oil bath lubrication, long service life of driving parts

● the flow can be adjusted under shutdown or operation, and the adjustment mode can be manual, electric or frequency conversion

Hydraulic end

● the diaphragm is mechanically driven, and there is no diaphragm protection plate on the material side to facilitate the passage of materials

● PVC, PVDF. 316SS. High viscosity, slurry and other pump head materials, suitable for all kinds of materials

● self cleaning check valve structure

Main application

● municipal, industrial water and wastewater, swimming pool and other water treatment processes

control mode 

◆ the electric stroke controller receives the external control signal and adjusts the stroke length

● power supply: 220V-50HZ single phase

● input signal: 4-20mA analog signal

● output signal: 4-20mA / 1-5V analog signal for recording, display and control system

◆ variable frequency controller, which receives external control signals and adjusts stroke speed

● power supply: 220v-50hz-single phase / 380-50hz-three phase

● input signal: 4-20mA analog signal

◆ the motor controller controls the three-phase motor in the "on / off" mode to adjust the output flow

● power supply: 200 - 240V / 50 / 60Hz / single phase

● control mode: it can accept 4-20mA analog signal, external pulse signal or manual adjustment

GM pump

Pump head material

GM0002 -GM0050

GM0090-GM0500

Interface codeABCInterface codeABC
PVCP108116250
Q127159
322
PVDFP108N131
316N102N131


Material of main components of hydraulic end

GM0002-GM0500

Material of 

hydraulic end

Valve body

Valve seatValve ball

The

 diaphragm

Seal ringConnect
PVCPVCPVDFZirconiaPTFEFPM/EPDM*/Fluorinated*PVC
PVDFPVDFPVDFZirconiaPTFEFPM/EPDM*/Fluorinated*PVDF
316SS316SS316SS316SSPTFEFPM/EPDM*/Fluorinated*316SS


Model definition of GM series mechanical diaphragm metering pump

Series

Code

Describe

GM

GM series mechanical diaphragm metering pump


Flow

Code

Maximum flow(L/h)

Maximum 

pressure

(bar)

Number of strokes(min¯¹)electric machinery(kw)
GM0002
2.2512
36

0.25●

0.37■


GM00054.536
GM0010936
GM00252572
GM00505010144
GM0090857
72
GM012011572
GM0170170144
GM0240235144
GM03303155
144
GM04004001440.37
GM0500500180

●This power is used for three-phase constant speed, explosion-proof motor    ■This power is used for single-phase, explosion-proof, variable-frequency motor 

Hydraulic end

Code

Describe

CodeDescribe
PPVC Hydraulic endVHigh viscosity application: PVC hydraulic end
S316 Hydraulic endKSlurry application:GM0025-0500
TPVDF Hydraulic endM

Mixture application, GM: PVDF hydraulic end

FApplication of sodium hypochlorite in PVC hydraulic end◆ZSpecial material hydraulic end, please consult factory, and explain when ordering

EPDM O-ring

Interface:

CodeDescribeGM0002-0050GM0090-0500
PVCPVDF316
PVCPVDF316
PNPT threaded connection1/2”F1/2”F1/2”F1/2”F1/2”F1/2”F
QHard tube intubation interface of inner tube orificeDN15————DN15————
RHose connection6×12▲6.35×9.52★————————
H

GM hose for high viscosity applications

12×18————20×28————
XSpecial interface
Please consult factory and explain when ordering

Note: the parameters in red are standard configuration. If there are no special options for high viscosity pump head V, slurry pump head K and mixture pump head m, the interface shall be selected according to the material of hydraulic end.

The length of PVC hose is 6m / piece; One hose is configured by default. The factory is not equipped with injection valve, bottom valve, counterweight and Teflon hose. Please order extra and inquire from the factory.

Electric machinery:

Code

Describe

1

0.25kW, 1EC71,three-phase 380V,50Hz, 1440rpm, IP55/F

2
1/3P,NEMA56C,three-phase 380V,50Hz, 1440rpm, NEMA3/TEFC
3

0.37kW, IEC71,three phase explosion proof 380V,50Hz,1440rpm, IP55/F, dIIBT4

40.37kW, IEC71,three-phase 380V,50Hz, 1440rpm,IP55/F
50.25kW, IEC71,three-phase 220V, 50Hz,1440rpm, IP55/F
6

0.25kW, 1EC71,three phase frequency conversion 380V, 50Hz, 1440rpm, IP55/F, IC416

7

0.37kW, IEC71,three phase frequency conversion 380V, 50Hz, 1440rpm, IP55/F, IC416

8————————
9(5)The pump is not equipped with motor, and iec71 interface is reserved
9(6)0.37kW, 1EC71,single-phase 220V,50Hz, 1440rpm, IP55/F
9(8)————————
9For other motors, please consult factory


Adjust:

CodeDescribeRemarks
M
Manual stroke adjustment

Standard

 configuration

NElectric stroke adjustment,4- 20mA, 1PH- 50Hz-220V——
E——————————
FFrequency conversion control——